Opening or closing the door makes the switch on / off. A limit switch is set inside of the magnet catch to get holding / detection together. Tough and small.
1.Specification of Micro switch
・Contact arrangement Switch-over(Please see Circuit Diagram)
・Rating
Rated voltage
Resistance Load
AC125V
3A
DC30V
3A
・Insulation Resistance 100MΩ Min.(at 500V DC Megger)
Dielectric Strength:
Between unconnected terminal 1000V AC/ min.
Between terminal and unconnected metal plate 1500V AC/ min
Betwen Current-Carrying Metal Part and Ground 1500V AC/min.
Electrical Life Expectancy 70,000 Operations Min.
2.Magnet
・Holding Force approx. 19.6N(2kgf) or more(with attached keeper)
3.Environment
・Ambient Operating Temperatures Range
-25℃ to 85℃(No frozen and dew condensation.)
Avoid using or storing in a condition with inflammable gas, corrosive gas or silicon rich atmosphere, also in an excessively dust place. This product can not be used as a stopper.Please install stopper separately. Manual soldering should be accomplished within 3 seconds with max. 350℃ iron. Care should be taken not to apply force to the Terminals during soldering. Terminal portions must not be moved in 1 minute after soldering. Please avoid adding load to switch part from oblique angle when installing. Use M3 screw to install keeper. Installation holes should be chamfered.